Protein Solubilizer 40, Sterile 10% of NP-40 Ampoules

SKU
P-1505
  • CAS:9016-45-9
  • Formula:C32H58O10
  • MW:603 Da
  • Appearance:Clear colorless solution

2

1

0

Product Name Qty
Protein Solubilizer 40, NP-40, Ampoules - 10x5ml
10x 5 ml
$87.11

Description

Protein Solubilizer 40 is a non-ionic surfactant with extremely low levels of conductivity. Its chemical name is Nonylphenyl-polyethylene glycol. It has very low peroxide and aldehyde impurities, which enables a high retention of activity for proteins.

It can be reconstituted with 100 mL of sterile, distilled water. If it is diluted further it should be with a medium that contains 5 percent fetal calf serum. It should be stored at room temperature in a cool dry area and protected from light.

 

Applications

• Lysing, isolation, and purification of functional membrane proteins and plant proteins
• Gel electrophoresis

 

Specifications

• CMC 0.05-0.3mM
• HLB 13.1
• Cloud Point: 80°C
• 10% aqueous solution of NP-40

 

More Information
Alternate Name/Synonyms
Nonylphenyl Polyethylene Glycol; Nonoxynol; Lissapol; Synperonic
SKU
P-1505
CAS #
9016-45-9
Chemical Name
Nonylphenyl-polyethylene glycol
Chemical Formula
C32H58O10
Molecular Weight
603 Da
Appearance
Clear colorless solution
Purity
N/A
Solubility
Soluble in water.
Melting Point
N/A
Preparation
N/A
Storage Temp
Room temperature
THERAPEUTIC AREA
Breast Cancer
USE
Protein Solubilizer 40, Sterile 10% of NP-40 Ampoules is an alternative form of Nonidet P-40, which functions as a polyglycol ether (non-ionic) surfactant that is useful in isolating and purifying membrane proteins in two dimensional gel electrophoresis. Studies indicate that it can be employed to solubilize cerebral GABA receptors. Also it is an efficient tool to study breast cancer by functioning as a solubilizing agent interacting with membrane proteins and lipids. Furthermore, it is beneficial in the extraction of MHC proteins and the zwitterionic detergent CHAPS (sc-29088).
Merck Index
13, 7641.
MDL NUMBER
MFCD00132851
CHEMACX
X1209386-6
Handling
Use only in area provided with appropriate exhaust ventilation. Keep away from heat and source of ignition. Empty containers pose a fire risk, evaporate residue under fume hood. Ground all equipment containing material. Do not breathe dust.
Certificate of Analysis 1
Certificate of Analysis 2
Certificate of Analysis 3
GHS PICTOGRAMS
Handling Use only in area provided with appropriate exhaust ventilation. Keep away from heat and source of ignition. Empty containers pose a fire risk, evaporate residue under fume hood. Ground all equipment containing material. Do not breathe dust.
We found other products you might like!